Assessment Year | 1993 |
---|---|
Principal Product | AGRICULTURAL CHEMICALS |
NAICS |
n/a
|
SIC | 2879: Pesticides and Agricultural Chemicals, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 160 |
Plant Area |
n/a
|
Annual Production | 64,170,000
lb
|
Production Hrs. Annual | 4,064
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $357,964 | 7,681,126 |
kWh
|
$0.047 |
Natural Gas | $1,670 | 371 |
MMBtu
|
$4.50 |
Other Energy | $579,870 | 141,755 |
MMBtu
|
$4.09 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $59,142 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $36,568 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Other Energy Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.8121: Apply for tax-free status for energy purchases | $16,869 | - |
$17,769
-
kWh
|
- | $(-900.0) | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $16,646 | $25,800 |
$16,646
357,268
kWh
|
- | - | |
03 | 2.2449: Recover heat from exhausted steam, hot air or hot water | $15,800 | $4,500 | - |
$15,800
-
MMBtu
|
- | |
04 | 2.4314: Use synthetic lubricant | $3,496 | - |
$3,496
75,029
kWh
|
- | - | |
05 | 2.4133: Use most efficient type of electric motors | $984 | $884 |
$984
21,102
kWh
|
- | - | |
06 | 2.7261: Install timers and/or thermostats | $2,507 | $3,060 | - |
$2,507
-
MMBtu
|
- | |
07 | 2.2135: Repair and eliminate steam leaks | $1,392 | $100 | - |
$1,392
-
MMBtu
|
- | |
08 | 2.7124: Make a practice of turning off lights when not needed | $1,106 | $2,346 |
$1,106
23,740
kWh
|
- | - | |
09 | 2.4221: Install compressor air intakes in coolest locations | $342 | $176 |
$342
7,327
kWh
|
- | - | |
TOTAL RECOMMENDED | $59,142 | $36,866 |
$40,343
484,466
kWh
|
$19,699
-
MMBtu
|
$(-900.0) | ||
TOTAL IMPLEMENTED | $36,568 | $7,660 |
$17,769
-
kWh
|
$19,699
-
MMBtu
|
$(-900.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Other Energy Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs