Assessment Year | 2006 |
---|---|
Principal Product | Flexible Packaging Products |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | n/a |
# of Employees | 53 |
Plant Area |
117,000
ft2
|
Annual Production | 43,000
thousand feet
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $180,899 | 3,826,074 |
kWh
|
$0.047 |
Electricity Demand | $100,294 | 9,591 |
kW-mo/yr
|
$10.46 |
Natural Gas | $74,076 | 4,869 |
MMBtu
|
$15.21 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $116,116 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,633 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $37,010 | $71,812 |
$29,870
622,267
kWh
|
$7,140
-
kW-mo/yr
|
- | |
02 | 2.3212: Optimize plant power factor | $24,700 | $17,000 |
$17,560
355,056
kWh
|
$7,140
-
kW-mo/yr
|
- | |
03 | 2.2414: Use waste heat from hot flue gases to preheat | $3,158 | $1,938 | - | - |
$3,158
-
MMBtu
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,417 | $10,049 |
$5,062
62,869
kWh
|
$1,355
-
kW-mo/yr
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $14,705 | $62,192 |
$10,363
215,904
kWh
|
$4,342
-
kW-mo/yr
|
- | |
06 | 2.7135: Install occupancy sensors | $1,990 | $227 |
$1,990
41,458
kWh
|
- | - | |
07 | 2.4133: Use most efficient type of electric motors | $19,036 | $27,664 |
$13,389
279,512
kWh
|
$5,647
-
kW-mo/yr
|
- | |
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $8,457 | - |
$8,457
108,994
kWh
|
- | - | |
09 | 2.6218: Turn off equipment when not in use | $643 | - |
$455
9,400
kWh
|
$188
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $116,116 | $190,882 |
$87,146
1,695,460
kWh
|
$25,812
-
kW-mo/yr
|
$3,158
-
MMBtu
|
||
TOTAL IMPLEMENTED | $2,633 | $227 |
$2,445
50,858
kWh
|
$188
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs