Assessment Year 1992
Principal Product T-SHIRTS
NAICS
n/a
SIC 2253: Knit Outerwear Mills
Sales Range $10
M
to 50
M
# of Employees 615
Plant Area
n/a
Annual Production 700,000
pieces
Production Hrs. Annual 8,592
hrs
Location (State) Kansas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $275,361 3,291,618
kWh
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $232,536 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $11,682

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings LPG Savings Administrative Changes Savings
01 2.3413: Burn fossil fuel to produce steam to drive a steam turbine-generator and use steam exhaust for heat $180,344 - $276,830
3,308,910
kWh
$(-46,852.0)
-
MMBtu
- $(-49,634.0)
02 2.2449: Recover heat from exhausted steam, hot air or hot water $20,311 $10,200 - $20,311
-
MMBtu
- -
03 2.1393: Use steam sparging or injections in place of indirect heating $8,568 $9,570 - $8,568
-
MMBtu
- -
04 2.1331: Burn a less expensive grade of fuel $4,504 - - $(-5,560.0)
-
MMBtu
$10,064
-
MMBtu
-
05 2.2414: Use waste heat from hot flue gases to preheat $3,643 $3,800 - $3,643
-
MMBtu
- -
06 2.2444: Use hot process fluids to preheat incoming process fluids $3,635 $5,600 - $3,635
-
MMBtu
- -
07 2.6232: Install set-back timers $3,237 $1,000 $3,237
38,687
kWh
- - -
08 2.7142: Utilize higher efficiency lamps and/or ballasts $1,430 - $1,588
19,050
kWh
- - $(-158.0)
09 2.6232: Install set-back timers $1,251 $285 $1,251
14,947
kWh
- - -
10 2.7142: Utilize higher efficiency lamps and/or ballasts $711 $891 $711
8,499
kWh
- - -
11 2.4221: Install compressor air intakes in coolest locations $1,839 $420 $1,839
21,981
kWh
- - -
12 2.2428: Use flue gases in radiant heater for space heating, ovens, etc $1,696 $1,250 $(-172.0)
(-2,052)
kWh
$1,868
-
MMBtu
- -
13 2.2437: Recover waste heat from equipment $1,013 $2,973 - $1,013
-
MMBtu
- -
14 2.2511: Insulate bare equipment $354 $406 $354
41,618
kWh
- - -
TOTAL RECOMMENDED $232,536 $36,395 $285,638
3,451,640
kWh
$(-13,374.0)
-
MMBtu
$10,064
-
MMBtu
$(-49,792.0)
TOTAL IMPLEMENTED $11,682 $5,470 $1,667
19,929
kWh
$(-49.0)
-
MMBtu
$10,064
-
MMBtu
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings LPG Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs