Assessment Year | 1992 |
---|---|
Principal Product | MILLWORK,BI-FOLD DOORS |
NAICS |
n/a
|
SIC | 2431: Millwork |
Sales Range | $10 M to 50M |
# of Employees | 350 |
Plant Area |
n/a
|
Annual Production | 1,900,000
pieces
|
Production Hrs. Annual | 4,000
hrs
|
Location (State) | Kansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $185,668 | 5,446,366 |
kWh
|
$0.034 |
Natural Gas | $34,372 | 7,890 |
MMBtu
|
$4.36 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $9,593 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,373 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,028 | $4,050 |
$2,028
59,496
kWh
|
- | - | |
02 | 2.4221: Install compressor air intakes in coolest locations | $1,119 | $1,080 |
$1,119
32,825
kWh
|
- | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $440 | $30 |
$440
12,896
kWh
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,367 | $5,928 |
$3,367
98,769
kWh
|
- | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $853 | - |
$1,079
31,653
kWh
|
- | $(-226.0) | |
06 | 2.7261: Install timers and/or thermostats | $1,786 | $2,365 |
$1,389
40,739
kWh
|
$397
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $9,593 | $13,453 |
$9,422
276,378
kWh
|
$397
-
MMBtu
|
$(-226.0) | ||
TOTAL IMPLEMENTED | $5,373 | $7,525 |
$4,976
145,956
kWh
|
$397
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs