Assessment Year | 1992 |
---|---|
Principal Product | FOLDING CARTONS |
NAICS |
n/a
|
SIC | 2657: Folding Paperboard Boxes, Including Sanitary |
Sales Range | $10 M to 50M |
# of Employees | 110 |
Plant Area |
n/a
|
Annual Production | 11,762
ton
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $202,204 | 3,236,811 |
kWh
|
$0.062 |
Natural Gas | $35,410 | 8,518 |
MMBtu
|
$4.16 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $18,553 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,352 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.8113: Purchase gas directly from a contract gas supplier | $5,666 | - | - |
$7,666
-
MMBtu
|
$(-2,000.0) | |
02 | 2.2437: Recover waste heat from equipment | $2,849 | - | - |
$2,849
-
MMBtu
|
- | |
03 | 2.4221: Install compressor air intakes in coolest locations | $2,893 | $1,380 |
$2,893
46,307
kWh
|
- | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $275 | $80 |
$275
4,396
kWh
|
- | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,816 | $2,607 |
$2,816
45,135
kWh
|
- | - | |
06 | 2.6232: Install set-back timers | $2,508 | $1,900 |
$2,508
40,152
kWh
|
- | - | |
07 | 2.4133: Use most efficient type of electric motors | $406 | - |
$207
3,224
kWh
|
- | $199 | |
08 | 2.4133: Use most efficient type of electric motors | $170 | - |
$132
2,052
kWh
|
- | $38 | |
09 | 2.4133: Use most efficient type of electric motors | $412 | $200 |
$412
6,741
kWh
|
- | - | |
10 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $549 | $40 |
$549
8,792
kWh
|
- | - | |
11 | 3.4154: Eliminate leaks in water lines and valves | $9 | - | - | - | $9 | |
TOTAL RECOMMENDED | $18,553 | $6,207 |
$9,792
156,799
kWh
|
$10,515
-
MMBtu
|
$(-1,754.0) | ||
TOTAL IMPLEMENTED | $6,352 | $2,887 |
$3,503
56,272
kWh
|
$2,849
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs