ITAC Assessment: AM0093
ITAC logo
ITAC Assessment: AM0093
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1990
Principal Product SOFT DRINKS
NAICS
n/a
SIC 2086: Bottled and Canned Soft Drinks and Carbonated Waters
Sales Range $10
M
to 50
M
# of Employees 74
Plant Area
n/a
Annual Production 5,500,000
pieces
Production Hrs. Annual 5,334
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $176,276 2,786,049
kWh
Natural Gas $45,314 11,216
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $18,317 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $14,830

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.2135: Repair and eliminate steam leaks $10,825 $1,000 - $10,825
-
MMBtu
02 2.2414: Use waste heat from hot flue gases to preheat $3,020 $9,750 $(-5,720.0)
(-99,648)
kWh
$8,740
-
MMBtu
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,575 $700 $2,575
63,599
kWh
-
04 2.2511: Insulate bare equipment $640 $370 $640
15,826
kWh
-
05 2.4221: Install compressor air intakes in coolest locations $460 $300 $460
11,430
kWh
-
06 2.3132: Recharge batteries on during off-peak demand periods $330 - $330
-
kWh
-
07 2.2511: Insulate bare equipment $290 $710 - $290
-
MMBtu
08 2.7142: Utilize higher efficiency lamps and/or ballasts $37 $27 $37
586
kWh
-
09 2.6232: Install set-back timers $140 - $140
3,517
kWh
-
TOTAL RECOMMENDED $18,317 $12,857 $(-1,538.0)
(-4,690)
kWh
$19,855
-
MMBtu
TOTAL IMPLEMENTED $14,830 $2,370 $4,005
90,855
kWh
$10,825
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs