Assessment Year | 1991 |
---|---|
Principal Product | TRAVEL TRIALERS |
NAICS |
n/a
|
SIC | 3792: Travel Trailers and Campers |
Sales Range | $10 M to 50M |
# of Employees | 200 |
Plant Area |
n/a
|
Annual Production | 1,300
pieces
|
Production Hrs. Annual | 2,134
hrs
|
Location (State) | Nebraska |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $67,898 | 1,185,522 |
kWh
|
$0.057 |
Natural Gas | $34,751 | 9,189 |
MMBtu
|
$3.78 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,595 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,595 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.6212: Turn off equipment during breaks, reduce operating time | $2,719 | $500 |
$889
15,533
kWh
|
$1,830
-
MMBtu
|
|
02 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,121 | $200 |
$168
2,931
kWh
|
$953
-
MMBtu
|
|
03 | 2.7221: Lower temperature during the winter season and vice-versa | $1,943 | - | - |
$1,943
-
MMBtu
|
|
04 | 2.2437: Recover waste heat from equipment | $197 | $250 | - |
$197
-
MMBtu
|
|
05 | 2.6232: Install set-back timers | $1,059 | $100 |
$1,059
18,464
kWh
|
- | |
06 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $470 | $825 |
$470
8,206
kWh
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $121 | $109 |
$121
2,052
kWh
|
- | |
08 | 2.4221: Install compressor air intakes in coolest locations | $453 | $100 |
$453
7,913
kWh
|
- | |
09 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $311 | - |
$436
7,620
kWh
|
$(-125.0)
-
MMBtu
|
|
10 | 2.6121: Reduce hot water temperature to the minimum required | $201 | - |
$201
3,517
kWh
|
- | |
TOTAL RECOMMENDED | $8,595 | $2,084 |
$3,797
66,236
kWh
|
$4,798
-
MMBtu
|
||
TOTAL IMPLEMENTED | $8,595 | $2,084 |
$3,797
66,236
kWh
|
$4,798
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs