Assessment Year | 1988 |
---|---|
Principal Product | PERIODICALS & BOOKS |
NAICS |
n/a
|
SIC | 2731: Books: Publishing, or Publishing and Printing |
Sales Range | $10 M to 50M |
# of Employees | 285 |
Plant Area |
n/a
|
Annual Production | 2,800,000
pieces
|
Production Hrs. Annual | 5,100
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $177,099 | 2,179,660 |
kWh
|
$0.081 |
Natural Gas | $21,420 | 5,307 |
MMBtu
|
$4.04 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $19,832 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $14,923 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7226: Use computer programs to optimize hvac performance | $4,182 | $7,500 |
$4,182
51,583
kWh
|
- | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,238 | $200 |
$3,238
39,859
kWh
|
- | - | |
03 | 2.7233: Use properly designed and sized hvac equipment | $2,500 | $3,600 |
$2,500
30,774
kWh
|
- | - | |
04 | 2.7233: Use properly designed and sized hvac equipment | $2,095 | $1,200 |
$2,095
25,791
kWh
|
- | - | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,381 | - |
$1,381
16,999
kWh
|
- | - | |
06 | 2.1233: Analyze flue gas for proper air/fuel ratio | $308 | - | - |
$808
-
MMBtu
|
$(-500.0) | |
07 | 2.6232: Install set-back timers | $1,072 | $324 |
$1,072
13,189
kWh
|
- | - | |
08 | 2.7221: Lower temperature during the winter season and vice-versa | $414 | - |
$357
4,396
kWh
|
$57
-
MMBtu
|
- | |
09 | 2.4221: Install compressor air intakes in coolest locations | $167 | $200 |
$167
2,052
kWh
|
- | - | |
10 | 2.1233: Analyze flue gas for proper air/fuel ratio | $147 | - | - |
$347
-
MMBtu
|
$(-200.0) | |
11 | 2.6121: Reduce hot water temperature to the minimum required | $137 | - | - |
$137
-
MMBtu
|
- | |
12 | 2.6212: Turn off equipment during breaks, reduce operating time | $4,191 | - |
$4,191
51,583
kWh
|
- | - | |
TOTAL RECOMMENDED | $19,832 | $13,024 |
$19,183
236,226
kWh
|
$1,349
-
MMBtu
|
$(-700.0) | ||
TOTAL IMPLEMENTED | $14,923 | $8,024 |
$14,421
177,609
kWh
|
$1,002
-
MMBtu
|
$(-500.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs