Assessment Year | 1985 |
---|---|
Principal Product | AVIATION ELECTRONICS |
NAICS |
n/a
|
SIC | 3699: Electrical Machinery, Equipment, and Supplies, Not Elsewhere |
Sales Range | $10 M to 50M |
# of Employees | 250 |
Plant Area |
n/a
|
Annual Production | 12,000
pieces
|
Production Hrs. Annual | 4,250
hrs
|
Location (State) | Kansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $103,448 | 1,446,952 |
kWh
|
$0.071 |
Natural Gas | $7,088 | 1,567 |
MMBtu
|
$4.52 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $16,637 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $12,137 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7111: Reduce illumination to minimum necessary levels | $3,790 | $1,100 |
$3,790
53,048
kWh
|
- | |
02 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $3,286 | $1,500 |
$4,502
63,013
kWh
|
$(-1,216.0)
-
MMBtu
|
|
03 | 2.2211: Use optimum temperature | $2,973 | $2,000 |
$2,973
41,618
kWh
|
- | |
04 | 2.7261: Install timers and/or thermostats | $2,676 | $149 |
$796
11,137
kWh
|
$1,880
-
MMBtu
|
|
05 | 2.6212: Turn off equipment during breaks, reduce operating time | $859 | - |
$859
12,016
kWh
|
- | |
06 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $1,085 | $2,160 |
$1,487
20,809
kWh
|
$(-402.0)
-
MMBtu
|
|
07 | 2.7314: Reduce ventilation air | $877 | $100 | - |
$877
-
MMBtu
|
|
08 | 2.1123: Install automatic stack damper | $176 | $600 | - |
$176
-
MMBtu
|
|
09 | 2.7447: Install vinyl strip / high speed / air curtain doors | $155 | $280 |
$209
2,931
kWh
|
$(-54.0)
-
MMBtu
|
|
10 | 2.2511: Insulate bare equipment | $129 | $113 |
$147
2,052
kWh
|
$(-18.0)
-
MMBtu
|
|
11 | 2.7444: Close holes and openings in building such as broken windows | $233 | $14 |
$21
293
kWh
|
$212
-
MMBtu
|
|
12 | 2.4231: Reduce the pressure of compressed air to the minimum required | $189 | $20 |
$189
2,638
kWh
|
- | |
13 | 2.6121: Reduce hot water temperature to the minimum required | $209 | - |
$209
2,931
kWh
|
- | |
TOTAL RECOMMENDED | $16,637 | $8,036 |
$15,182
212,486
kWh
|
$1,455
-
MMBtu
|
||
TOTAL IMPLEMENTED | $12,137 | $4,263 |
$9,046
126,612
kWh
|
$3,091
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs