Assessment Year | 1984 |
---|---|
Principal Product | BRASS PLUMBING SUPPLIES |
NAICS |
n/a
|
SIC | 3432: Plumbing Fixture Fittings and Trim |
Sales Range | $10 M to 50M |
# of Employees | 200 |
Plant Area |
n/a
|
Annual Production | 4,000,000
lb
|
Production Hrs. Annual | 4,550
hrs
|
Location (State) | Kansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $244,765 | 3,791,911 |
kWh
|
$0.065 |
Natural Gas | $74,843 | 15,472 |
MMBtu
|
$4.84 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $54,514 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $45,856 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $23,486 | - |
$23,486
364,009
kWh
|
- | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $12,840 | - |
$12,840
199,004
kWh
|
- | - | |
03 | 2.4312: Improve lubrication practices | $3,966 | - |
$9,966
154,455
kWh
|
- | $(-6,000.0) | |
04 | 2.3191: Use demand controller or load shedder | $4,586 | $3,000 |
$4,586
-
kWh
|
- | - | |
05 | 2.1122: Re-size charging openings or add a movable door on equipment | $4,141 | $2,000 |
$4,141
64,185
kWh
|
- | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,229 | $650 |
$1,229
19,050
kWh
|
- | - | |
07 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $1,043 | $1,200 |
$1,532
23,740
kWh
|
$(-489.0)
-
MMBtu
|
- | |
08 | 2.2511: Insulate bare equipment | $755 | $500 | - |
$755
-
MMBtu
|
- | |
09 | 2.2511: Insulate bare equipment | $663 | $1,200 | - |
$663
-
MMBtu
|
- | |
10 | 2.7441: Replace broken windows and/or window sash | $620 | $920 | - |
$620
-
MMBtu
|
- | |
11 | 2.6121: Reduce hot water temperature to the minimum required | $548 | - |
$548
8,499
kWh
|
- | - | |
12 | 2.4221: Install compressor air intakes in coolest locations | $454 | $300 |
$454
7,034
kWh
|
- | - | |
13 | 2.7221: Lower temperature during the winter season and vice-versa | $183 | - |
$38
586
kWh
|
$145
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $54,514 | $9,770 |
$58,820
840,562
kWh
|
$1,694
-
MMBtu
|
$(-6,000.0) | ||
TOTAL IMPLEMENTED | $45,856 | $5,920 |
$45,091
627,784
kWh
|
$765
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs