Assessment Year | 1983 |
---|---|
Principal Product | BACKHOES, FORKLIFTS |
NAICS |
n/a
|
SIC | 3537: Industrial Trucks, Tractors, Trailers, and Stackers |
Sales Range | $5 M to 10M |
# of Employees | 165 |
Plant Area |
n/a
|
Annual Production | 1,500
pieces
|
Production Hrs. Annual | 4,165
hrs
|
Location (State) | Kansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $130,074 | 2,589,977 |
kWh
|
$0.050 |
Natural Gas | $31,924 | 6,209 |
MMBtu
|
$5.14 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $55,952 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $476 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7447: Install vinyl strip / high speed / air curtain doors | $17,326 | $5,429 | - |
$17,326
-
MMBtu
|
|
02 | 2.7261: Install timers and/or thermostats | $15,389 | $50,000 | - |
$15,389
-
MMBtu
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,504 | $5,569 |
$3,504
69,754
kWh
|
- | |
04 | 2.2532: Use only amount of air necessary to prevent explosion hazard | $17,707 | $200 | - |
$17,707
-
MMBtu
|
|
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $795 | $152 |
$795
15,826
kWh
|
- | |
06 | 2.1233: Analyze flue gas for proper air/fuel ratio | $591 | $20 | - |
$591
-
MMBtu
|
|
07 | 2.1123: Install automatic stack damper | $476 | $825 | - |
$476
-
MMBtu
|
|
08 | 2.1123: Install automatic stack damper | $164 | $375 | - |
$164
-
MMBtu
|
|
TOTAL RECOMMENDED | $55,952 | $62,570 |
$4,299
85,580
kWh
|
$51,653
-
MMBtu
|
||
TOTAL IMPLEMENTED | $476 | $825 | - |
$476
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs