ITAC Assessment: KU0086
ITAC logo
ITAC Assessment: KU0086
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1983
Principal Product BOOK BINDING
NAICS
n/a
SIC 2789: Bookbinding and Related Work
Sales Range $1
M
to 5
M
# of Employees 80
Plant Area
n/a
Annual Production 1,000,000
pieces
Production Hrs. Annual 2,185
hrs
Location (State) Kansas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $27,198 518,464
kWh
Natural Gas $7,971 1,986
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $9,261 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.7261: Install timers and/or thermostats $4,657 $1,500 $2,997
57,151
kWh
$1,660
-
MMBtu
02 2.7447: Install vinyl strip / high speed / air curtain doors $2,333 $146 $123
2,345
kWh
$2,210
-
MMBtu
03 2.7243: Improve air circulation with destratification fans / other methods $866 - - $866
-
MMBtu
04 2.1123: Install automatic stack damper $489 $624 - $489
-
MMBtu
05 2.1123: Install automatic stack damper $489 $1,012 $489
35,756
kWh
-
06 2.1233: Analyze flue gas for proper air/fuel ratio $427 $260 - $427
-
MMBtu
TOTAL RECOMMENDED $9,261 $3,542 $3,609
95,252
kWh
$5,652
-
MMBtu
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs