Assessment Year | 1983 |
---|---|
Principal Product | WALNUT LUMBER |
NAICS |
n/a
|
SIC | 2421: Sawmills and Planing Mills, General |
Sales Range | $1 M to 5M |
# of Employees | 44 |
Plant Area |
n/a
|
Annual Production | 3,500
thousand feet
|
Production Hrs. Annual | 2,125
hrs
|
Location (State) | Kansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $101,636 | 1,596,424 |
kWh
|
$0.064 |
Natural Gas | $33,989 | 10,086 |
MMBtu
|
$3.37 |
Wood | $294,185 | 152,409 |
MMBtu
|
$1.93 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $89,417 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $89,417 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Wood Savings |
---|---|---|---|---|---|---|---|
01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $24,439 | $1,400 | - |
$3,044
-
MMBtu
|
$21,395
-
MMBtu
|
|
02 | 2.5123: Reduce fluid flow rates | $26,145 | $2,920 | - |
$3,257
-
MMBtu
|
$22,888
-
MMBtu
|
|
03 | 2.1243: Use heat from boiler blowdown to preheat boiler feed water | $14,284 | $5,200 | - |
$1,779
-
MMBtu
|
$12,505
-
MMBtu
|
|
04 | 2.1131: Repair faulty insulation in furnaces, boilers, etc | $4,370 | $1,756 | - |
$544
-
MMBtu
|
$3,826
-
MMBtu
|
|
05 | 2.2136: Install / repair insulation on steam lines | $1,448 | $358 | - |
$180
-
MMBtu
|
$1,268
-
MMBtu
|
|
06 | 2.2135: Repair and eliminate steam leaks | $2,905 | $100 | - |
$362
-
MMBtu
|
$2,543
-
MMBtu
|
|
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $841 | $238 |
$841
13,189
kWh
|
- | - | |
08 | 2.7447: Install vinyl strip / high speed / air curtain doors | $12,687 | $9,759 | - |
$1,580
-
MMBtu
|
$11,107
-
MMBtu
|
|
09 | 2.6212: Turn off equipment during breaks, reduce operating time | $851 | $306 |
$851
13,482
kWh
|
- | - | |
10 | 2.6212: Turn off equipment during breaks, reduce operating time | $897 | - |
$897
14,068
kWh
|
- | - | |
11 | 2.4231: Reduce the pressure of compressed air to the minimum required | $345 | - |
$345
5,569
kWh
|
- | - | |
12 | 2.4221: Install compressor air intakes in coolest locations | $205 | $150 |
$205
3,224
kWh
|
- | - | |
TOTAL RECOMMENDED | $89,417 | $22,187 |
$3,139
49,532
kWh
|
$10,746
-
MMBtu
|
$75,532
-
MMBtu
|
||
TOTAL IMPLEMENTED | $89,417 | $22,187 |
$3,139
49,532
kWh
|
$10,746
-
MMBtu
|
$75,532
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Wood Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs