Assessment Year | 2015 |
---|---|
Principal Product | Chillers |
NAICS | 333415: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipmen |
SIC | 3585: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment |
Sales Range | $100 M to 500M |
# of Employees | 465 |
Plant Area |
600,000
ft2
|
Annual Production | 2,330
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Virginia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $922,100 | 14,587,740 |
kWh
|
$0.063 |
Electricity Demand | $194,200 | 53,677 |
kW-mo/yr
|
$3.62 |
Natural Gas | $269,302 | 52,354 |
MMBtu
|
$5.14 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $59,266 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $14,174 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.2437: Recover waste heat from equipment | $23,830 | $85,000 | - |
$23,830
-
MMBtu
|
- | - | |
02 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $13,922 | $5,000 |
$13,922
-
kWh
|
- | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,958 | $6,100 |
$3,958
62,832
kWh
|
- | - | - | |
04 | 2.1243: Use heat from boiler blowdown to preheat boiler feed water | $4,478 | $7,000 | - |
$4,478
-
MMBtu
|
- | - | |
05 | 2.2121: Increase amount of condensate returned | $6,019 | $1,500 | - |
$6,019
-
MMBtu
|
- | - | |
06 | 2.4239: Eliminate or reduce compressed air usage | $1,418 | $7,500 |
$1,418
22,500
kWh
|
- | - | - | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $708 | $100 |
$1,128
17,904
kWh
|
- | $(-300.0) | $(-120.0) | |
08 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,444 | $100 |
$1,444
22,920
kWh
|
- | - | - | |
09 | 2.4151: Develop a repair/replace policy | $1,904 | $4,258 |
$1,904
30,221
kWh
|
- | - | - | |
10 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,585 | $281 |
$1,585
25,154
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $59,266 | $116,839 |
$25,359
181,531
kWh
|
$34,327
-
MMBtu
|
$(-300.0) | $(-120.0) | ||
TOTAL IMPLEMENTED | $14,174 | $12,239 |
$8,575
136,111
kWh
|
$6,019
-
MMBtu
|
$(-300.0) | $(-120.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs