| Assessment Year | 1982 |
|---|---|
| Principal Product | CORRUGATED BOXES |
| NAICS |
n/a
|
| SIC | 2653: Corrugated and Solid Fiber Boxes |
| Sales Range | $10 M to 50M |
| # of Employees | 109 |
| Plant Area |
n/a
|
| Annual Production | 500,000
thousand feet
|
| Production Hrs. Annual | 6,072
hrs
|
| Location (State) | Kansas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $155,901 | 2,530,481 |
kWh
|
$0.062 |
| Natural Gas | $98,693 | 32,521 |
MMBtu
|
$3.03 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $33,360 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,705 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,441 | $5,865 |
$7,441
120,750
kWh
|
- | |
| 02 | 2.7447: Install vinyl strip / high speed / air curtain doors | $4,532 | $230,000 | - |
$4,532
-
MMBtu
|
|
| 03 | 2.3212: Optimize plant power factor | $2,215 | $4,000 |
$2,215
-
kWh
|
- | |
| 04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $670 | - |
$670
10,844
kWh
|
- | |
| 05 | 2.4221: Install compressor air intakes in coolest locations | $173 | $82 |
$173
2,931
kWh
|
- | |
| 06 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,276 | $450 | - |
$1,276
-
MMBtu
|
|
| 07 | 2.2124: Install de-aerator in place of condensate tank | $17,053 | $57,400 | - |
$17,053
-
MMBtu
|
|
| TOTAL RECOMMENDED | $33,360 | $297,797 |
$10,499
134,525
kWh
|
$22,861
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $4,705 | $230,082 |
$173
2,931
kWh
|
$4,532
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs