Assessment Year | 1981 |
---|---|
Principal Product | PRINTED PAPER PRODUCTS |
NAICS |
n/a
|
SIC | 2759: Commercial Printing, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 80 |
Plant Area |
n/a
|
Annual Production | 2,500,000
lb
|
Production Hrs. Annual | 2,040
hrs
|
Location (State) | Kansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $38,333 | 863,423 |
kWh
|
$0.044 |
Natural Gas | $5,811 | 2,033 |
MMBtu
|
$2.86 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $9,705 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,880 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,870 | $5,633 |
$3,870
87,339
kWh
|
- | |
02 | 2.7261: Install timers and/or thermostats | $2,320 | $1,500 |
$380
8,499
kWh
|
$1,940
-
MMBtu
|
|
03 | 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary | $770 | - |
$770
17,292
kWh
|
- | |
04 | 2.3191: Use demand controller or load shedder | $1,185 | $2,850 |
$1,185
-
kWh
|
- | |
05 | 2.7447: Install vinyl strip / high speed / air curtain doors | $940 | $1,950 |
$680
15,533
kWh
|
$260
-
MMBtu
|
|
06 | 2.7492: Use proper thickness of insulation on building envelope | $620 | $1,620 |
$450
10,258
kWh
|
$170
-
MMBtu
|
|
TOTAL RECOMMENDED | $9,705 | $13,553 |
$7,335
138,921
kWh
|
$2,370
-
MMBtu
|
||
TOTAL IMPLEMENTED | $3,880 | $5,070 |
$1,510
34,290
kWh
|
$2,370
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs