ITAC Assessment: KS2435
ITAC logo
ITAC Assessment: KS2435
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2025
Principal Product Fabricated Pipe Fittings
NAICS 332996: Fabricated Pipe and Pipe Fitting Manufacturing
SIC 3498: Fabricated Pipe and Pipe Fittings
Sales Range $10
M
to 50
M
# of Employees 81
Plant Area 35,000
ft2
Annual Production 250,000
pieces
Production Hrs. Annual 4,000
hrs
Location (State) Georgia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $47,180 686,280
kWh
Electricity Demand $59,366 2,301
kW-mo/yr
TOTAL YEARLY COSTS $106,546
RECOMMENDED SAVINGS* $31,279 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,169 $4,040 $550
8,000
kWh
$619
-
kW-mo/yr
02 2.4231: Reduce the pressure of compressed air to the minimum required $834 $90 $290
4,216
kWh
$544
-
kW-mo/yr
03 2.7442: Keep doors and windows shut when not on use $597 - $334
4,864
kWh
$263
-
kW-mo/yr
04 2.2449: Recover heat from exhausted steam, hot air or hot water $1,393 $3,705 $578
8,420
kWh
$815
-
kW-mo/yr
05 2.3131: Reschedule plant operations or reduce load to avoid peaks $2,807 - - $2,807
-
kW-mo/yr
06 2.9114: Use solar heat to make electricty $24,479 $193,329 $15,129
220,223
kWh
$9,350
-
kW-mo/yr
TOTAL RECOMMENDED $31,279 $201,164 $16,881
245,723
kWh
$14,398
-
kW-mo/yr
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs