Assessment Year | 1997 |
---|---|
Principal Product | Jean pants and shorts |
NAICS |
n/a
|
SIC | 2325: Men's and Boys' Separate Trousers and Slacks |
Sales Range | $100 M to 500M |
# of Employees | 630 |
Plant Area |
131,000
ft2
|
Annual Production | 6,000,000
pieces
|
Production Hrs. Annual | 2,083
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $202,681 | 6,399,766 |
kWh
|
$0.032 |
Electricity Demand | $119,939 | 18,280 |
kW-mo/yr
|
$6.56 |
Electricity Fees | $1,560 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $78,732 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7251: Reduce air conditioning load by evaporating water from roof | $9,336 | $250 | n/a |
$9,336
295,428
kWh
|
- | - | - |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $4,010 | $14,000 | n/a |
$4,010
114,596
kWh
|
- | - | - |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,669 | $604 | n/a |
$1,037
32,825
kWh
|
$632
-
kW-mo/yr
|
- | - |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,210 | $2,650 | n/a |
$753
23,740
kWh
|
$457
-
kW-mo/yr
|
- | - |
05 | 2.7261: Install timers and/or thermostats | $823 | $600 | n/a |
$823
26,084
kWh
|
- | - | - |
06 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $15,960 | - | n/a | - | - |
$15,960
-
lb
|
- |
07 | 3.5212: Regrind, reuse, or sell scrap plastic parts | $5,525 | - | n/a | - | - |
$5,525
-
lb
|
- |
08 | 3.5212: Regrind, reuse, or sell scrap plastic parts | $2,174 | $1,079 | n/a | - | - |
$2,174
-
lb
|
- |
09 | 4.321: Optimize production lot sizes and inventories | $38,025 | - | n/a | - | - | - | $38,025 |
TOTAL RECOMMENDED | $78,732 | $19,183 |
$15,959
492,673
kWh
|
$1,089
-
kW-mo/yr
|
$23,659
-
lb
|
$38,025 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs