Assessment Year 1995
Principal Product Heat Exchangers
NAICS
n/a
SIC 3441: Fabricated Structural Metal
Sales Range $5
M
to 10
M
# of Employees 1,150
Plant Area 295,330
ft2
Annual Production 18
pieces
Production Hrs. Annual 8,760
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $257,589 4,511,137
kWh
Natural Gas $37,943 13,784
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $35,505 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $26,421

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.4133: Use most efficient type of electric motors $13,012 $11,560 $13,012
303,634
kWh
02 2.7142: Utilize higher efficiency lamps and/or ballasts $9,861 $2,995 $9,861
167,937
kWh
03 2.7261: Install timers and/or thermostats $4,737 $600 $4,737
168,523
kWh
04 2.4221: Install compressor air intakes in coolest locations $4,347 $390 $4,347
93,787
kWh
05 2.4314: Use synthetic lubricant $3,548 - $3,548
76,495
kWh
TOTAL RECOMMENDED $35,505 $15,545 $35,505
810,376
kWh
TOTAL IMPLEMENTED $26,421 $14,555 $26,421
548,066
kWh
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs