Assessment Year 1995
Principal Product Pigments
NAICS
n/a
SIC 2816: Inorganic Pigments
Sales Range $10
M
to 50
M
# of Employees 35
Plant Area 125,937
ft2
Annual Production 40,000,000
lb
Production Hrs. Annual 6,240
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $246,262 2,659,437
kWh
Natural Gas $676,056 274,370
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $30,019 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $26,215

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.1233: Analyze flue gas for proper air/fuel ratio $13,216 $4,500 - $13,216
-
MMBtu
02 2.4133: Use most efficient type of electric motors $9,454 $24,440 $9,454
157,386
kWh
-
03 2.2515: Use optimum thickness insulation $2,733 $2,269 - $2,733
-
MMBtu
04 2.7261: Install timers and/or thermostats $1,327 $600 $1,327
40,152
kWh
-
05 2.7134: Use photocell controls $1,206 $945 $1,206
10,551
kWh
-
06 2.4221: Install compressor air intakes in coolest locations $1,071 $260 $1,071
17,878
kWh
-
07 2.7142: Utilize higher efficiency lamps and/or ballasts $1,012 $467 $1,012
9,672
kWh
-
TOTAL RECOMMENDED $30,019 $33,481 $14,070
235,639
kWh
$15,949
-
MMBtu
TOTAL IMPLEMENTED $26,215 $30,952 $12,999
217,761
kWh
$13,216
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs