| Assessment Year | 2024 |
|---|---|
| Principal Product | Metal Automotive Parts |
| NAICS | 336370: Motor Vehicle Metal Stamping |
| SIC | 3469: Metal Stampings, Not Elsewhere Classified |
| Sales Range | $50 M to 100M |
| # of Employees | 262 |
| Plant Area |
218,000
ft2
|
| Annual Production | 28,000,000
pieces
|
| Production Hrs. Annual | 6,260
hrs
|
| Location (State) | Indiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $448,019 | 7,080,914 |
kWh
|
$0.063 | |
| Electricity Demand | $233,713 | 14,717 |
kW-mo/yr
|
$15.88 | |
| Electricity Fees | $36,328 | - |
|
- | |
| Natural Gas | $20,968 | 2,358 |
MMBtu
|
$8.89 | |
| Waste Disposal Costs | |||||
| Water Usage | $7,230 | 1,359 |
Tgal
|
$5.32 | |
| Water Disposal | $13,441 | 1,351 |
Tgal
|
$9.95 | |
| TOTAL YEARLY COSTS | $759,699 | ||||
| RECOMMENDED SAVINGS* | $224,016 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.6218: Turn off equipment when not in use | $55,084 | - |
$55,084
874,348
kWh
|
- | - | - | |
| 02 | 3.1191: Change procedures / equipment / operating conditions | $9,654 | - |
$7,176
113,912
kWh
|
$2,478
-
kW-mo/yr
|
- | - | |
| 03 | 2.8117: Install sub-metering equipment | $3,904 | $700 | - | - | - |
$3,904
-
Tgal
|
|
| 04 | 2.6231: Utilize controls to operate equipment only when needed | $133,638 | $39,257 |
$133,638
2,121,235
kWh
|
- | - | - | |
| 05 | 2.2437: Recover waste heat from equipment | $4,991 | $1,471 | - | - |
$4,991
-
MMBtu
|
- | |
| 06 | 2.7135: Install occupancy sensors | $2,678 | $1,198 |
$1,805
28,646
kWh
|
$873
-
kW-mo/yr
|
- | - | |
| 07 | 2.4221: Install compressor air intakes in coolest locations | $3,237 | $2,101 |
$1,915
30,397
kWh
|
$1,322
-
kW-mo/yr
|
- | - | |
| 08 | 2.4322: Use or replace with energy efficient substitutes | $10,830 | $25,000 |
$8,334
132,289
kWh
|
$2,496
-
kW-mo/yr
|
- | - | |
| TOTAL RECOMMENDED | $224,016 | $69,727 |
$207,952
3,300,827
kWh
|
$7,169
-
kW-mo/yr
|
$4,991
-
MMBtu
|
$3,904
-
Tgal
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs