Assessment Year 2024
Principal Product Shocks and struts for the auto market
NAICS 336330: Motor Vehicle Steering and Suspension Components (except Spring) Manufacturing
SIC 3714: Motor Vehicle Parts and Accessories
Sales Range $100
M
to 500
M
# of Employees 440
Plant Area 565,000
ft2
Annual Production 8,200,000
pieces
Production Hrs. Annual 6,450
hrs
Location (State) Indiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $2,659,921 33,553,665
kWh
Electricity Demand $264,476 67,814
kW-mo/yr
Electricity Fees $(-74,624.0) -
Natural Gas $215,640 43,644
MMBtu
Waste Disposal Costs
Water Usage $136,416 32,808
Tgal
Water Disposal $189,999 32,808
Tgal
TOTAL YEARLY COSTS $3,391,828
RECOMMENDED SAVINGS* $261,046 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Disposal Savings
01 2.3132: Recharge batteries on during off-peak demand periods $5,456 - - $5,456
-
kW-mo/yr
- -
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,451 $75 $3,161
40,014
kWh
$290
-
kW-mo/yr
- -
03 2.4231: Reduce the pressure of compressed air to the minimum required $23,593 - $23,593
298,646
kWh
- - -
04 2.8117: Install sub-metering equipment $170,944 $700 - - - $170,944
-
Tgal
05 2.2437: Recover waste heat from equipment $16,999 $1,899 - - $16,999
-
MMBtu
-
06 2.4221: Install compressor air intakes in coolest locations $9,977 $921 $9,977
126,291
kWh
- - -
07 2.7224: Reduce space conditioning during non-working hours $6,262 $328 $2,015
25,510
kWh
- $4,247
-
MMBtu
-
08 2.6231: Utilize controls to operate equipment only when needed $12,218 $4,577 $12,218
154,653
kWh
- - -
09 2.1123: Install automatic stack damper $11,682 $7,629 $11,682
147,870
kWh
- - -
10 2.2514: Cover open tanks $129 $246 - - $129
-
MMBtu
-
11 2.7225: Close outdoor air dampers during warm-up / cool-down periods $335 $705 $1
12
kWh
- $334
-
MMBtu
-
TOTAL RECOMMENDED $261,046 $17,080 $62,647
792,996
kWh
$5,746
-
kW-mo/yr
$21,709
-
MMBtu
$170,944
-
Tgal
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Disposal Savings