ITAC Assessment: IP0072
ITAC logo
ITAC Assessment: IP0072
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2016
Principal Product Tool & Die
NAICS 332710: Machine Shops
SIC 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 50
Plant Area 51,563
ft2
Annual Production 303,000
lb
Production Hrs. Annual 5,096
hrs
Location (State) Indiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $59,407 934,511
kWh
Electricity Demand $36,540 6,252
kW-mo/yr
Electricity Fees $1,650 -
Natural Gas $6,291 839
MMBtu
TOTAL YEARLY COSTS $103,888
RECOMMENDED SAVINGS* $14,600 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $14,600

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.4322: Use or replace with energy efficient substitutes $935 - $830
13,052
kWh
$105
-
kW-mo/yr
02 2.4231: Reduce the pressure of compressed air to the minimum required $410 $4 $337
5,306
kWh
$73
-
kW-mo/yr
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,514 $85 $2,066
32,490
kWh
$448
-
kW-mo/yr
04 2.4322: Use or replace with energy efficient substitutes $4,720 $671 $4,720
74,211
kWh
-
05 2.7135: Install occupancy sensors $415 $78 $415
6,523
kWh
-
06 2.7261: Install timers and/or thermostats $1,837 $555 $1,837
28,888
kWh
-
07 2.4221: Install compressor air intakes in coolest locations $391 $768 $347
5,453
kWh
$44
-
kW-mo/yr
08 2.7142: Utilize higher efficiency lamps and/or ballasts $3,378 $6,703 $2,777
43,663
kWh
$601
-
kW-mo/yr
TOTAL RECOMMENDED $14,600 $8,864 $13,329
209,586
kWh
$1,271
-
kW-mo/yr
TOTAL IMPLEMENTED $14,600 $8,864 $13,329
209,586
kWh
$1,271
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs