| Assessment Year | 2015 | 
|---|---|
| Principal Product | Commercial Printing | 
| NAICS | 323111: Commercial Printing (except Screen and Books) | 
| SIC | 2752: Commercial Printing, Lithographic | 
| Sales Range | $10 M  to 50M  | 
    
| # of Employees | 105 | 
| Plant Area | 
                            55,000
                 
ft2
 
                     | 
    
| Annual Production | 1,000
             
lb
 
         | 
    
| Production Hrs. Annual | 6,868
             
hrs
 
         | 
    
| Location (State) | Indiana | 
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $105,106 | 1,786,840 | 
             
kWh
 
         | 
        $0.059 | 
| Electricity Demand | $51,178 | 4,834 | 
             
kW-mo/yr
 
         | 
        $10.59 | 
| Electricity Fees | $1,646 | - | 
             | 
        - | 
| Natural Gas | $11,446 | 1,322 | 
             
MMBtu
 
         | 
        $8.66 | 
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $43,173 | 
             See individual recommendations below 
            *Non-energy impacts included in savings.
         | 
    ||
| IMPLEMENTED SAVINGS* | $9,448 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | 
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,690 | - | 
                        $1,285
                                                     21,759
                                 
                                            
kWh
 
                             | 
                                                                                
                        $404
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                - | - | |
| 02 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $6,360 | - | - | 
                        $6,360
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                - | - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,057 | $167 | 
                        $4,057
                                                     68,766
                                 
                                            
kWh
 
                             | 
                                                                                - | - | - | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $2,828 | $665 | 
                        $2,474
                                                     41,939
                                 
                                            
kWh
 
                             | 
                                                                                
                        $354
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                - | - | |
| 05 | 2.7135: Install occupancy sensors | $10,659 | $801 | 
                        $10,659
                                                     180,661
                                 
                                            
kWh
 
                             | 
                                                                                - | - | - | |
| 06 | 2.7447: Install vinyl strip / high speed / air curtain doors | $3,713 | $310 | - | - | - | 
                        $3,713
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                    |
| 07 | 2.4234: Cool compressor air intake with heat exchanger | $1,476 | $340 | - | - | - | 
                        $1,476
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                    |
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,278 | $5,296 | 
                        $3,647
                                                     61,813
                                 
                                            
kWh
 
                             | 
                                                                                
                        $1,631
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                - | - | |
| 09 | 2.253: Infiltration | $5,896 | $5,317 | 
                        $5,896
                                                     99,924
                                 
                                            
kWh
 
                             | 
                                                                                - | - | - | |
| 10 | 2.3212: Optimize plant power factor | $1,104 | $5,400 | - | - | $1,104 | - | |
| 11 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $113 | $385 | 
                        $113
                                                     1,922
                                 
                                            
kWh
 
                             | 
                                                                                - | - | - | |
| TOTAL RECOMMENDED | $43,173 | $18,680 | 
                        $28,132
                                                     476,784
                                 
                                            
kWh
 
                             | 
                                                                                
                        $8,749
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                $1,104 | 
                        $5,189
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                    ||
| TOTAL IMPLEMENTED | $9,448 | $5,848 | 
                        $7,818
                                                     132,501
                                 
                                            
kWh
 
                             | 
                                                                                
                        $1,631
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs