ITAC Assessment: IC0340
ITAC logo
ITAC Assessment: IC0340
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2026
Principal Product Steel Drums
NAICS 332439: Other Metal Container Manufacturing
SIC 3412: Metal Shipping Barrels, Drums, Kegs, and Pails
Sales Range $10
M
to 50
M
# of Employees 66
Plant Area 65,000
ft2
Annual Production 800,000
units
Production Hrs. Annual 2,340
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $79,221 1,658,997
kWh
Electricity Demand $84,033 8,539
kW-mo/yr
Electricity Fees $52,089 -
Natural Gas $201,904 29,054
MMBtu
Other Gas $32,893 1
MMBtu
Waste Disposal Costs
Water Usage $84,889 7,162
Tgal
TOTAL YEARLY COSTS $535,029
RECOMMENDED SAVINGS* $18,601 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $442 - $318
6,774
kWh
$124
-
kW-mo/yr
-
02 2.2511: Insulate bare equipment $2,377 $458 - - $2,377
-
MMBtu
03 2.7135: Install occupancy sensors $1,529 $525 $380
8,088
kWh
$1,149
-
kW-mo/yr
-
04 2.7221: Lower temperature during the winter season and vice-versa $357 $850 $357
7,605
kWh
- -
05 2.4221: Install compressor air intakes in coolest locations $860 $986 $309
6,565
kWh
$552
-
kW-mo/yr
-
06 2.7444: Close holes and openings in building such as broken windows $5,977 $29,536 - - $5,977
-
MMBtu
07 2.6218: Turn off equipment when not in use $1,921 $1,431 $1,823
38,792
kWh
$98
-
kW-mo/yr
-
08 2.7142: Utilize higher efficiency lamps and/or ballasts $4,902 $18,245 $2,408
51,236
kWh
$2,494
-
kW-mo/yr
-
09 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $235 $1,669 $117
2,481
kWh
$119
-
kW-mo/yr
-
TOTAL RECOMMENDED $18,601 $53,700 $5,712
121,541
kWh
$4,535
-
kW-mo/yr
$8,354
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs