| Assessment Year | 2025 |
|---|---|
| Principal Product | Office Space and Material Testing Labs |
| NAICS | 551114: Corporate, Subsidiary, and Regional Managing Offices |
| SIC | 6541: Title Abstract Offices |
| Sales Range | less than $500 k |
| # of Employees | 100 |
| Plant Area |
17,976
ft2
|
| Annual Production | 1
units
|
| Production Hrs. Annual | 3,000
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $41,993 | 343,492 |
kWh
|
$0.12 |
| Electricity Demand | $4,525 | 873 |
kW-mo/yr
|
$5.18 |
| Electricity Fees | $1,043 | - |
|
- |
| Natural Gas | $12,587 | 2,158 |
MMBtu
|
$5.83 |
| TOTAL YEARLY COSTS | $60,147 | |||
| RECOMMENDED SAVINGS* | $22,771 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.9114: Use solar heat to make electricty | $14,194 | $77,871 |
$11,278
93,983
kWh
|
$2,916
-
kW-mo/yr
|
- | |
| 02 | 2.7444: Close holes and openings in building such as broken windows | $860 | $218 |
$296
2,471
kWh
|
$67
-
kW-mo/yr
|
$496
-
MMBtu
|
|
| 03 | 2.7261: Install timers and/or thermostats | $3,278 | $2,275 |
$3,278
27,316
kWh
|
- | - | |
| 04 | 2.2511: Insulate bare equipment | $1,913 | $1,710 |
$1,724
14,367
kWh
|
$189
-
kW-mo/yr
|
- | |
| 05 | 2.2511: Insulate bare equipment | $1,832 | $1,110 | - | - |
$1,832
-
MMBtu
|
|
| 06 | 2.4239: Eliminate or reduce compressed air usage | $445 | $150 |
$406
3,387
kWh
|
$39
-
kW-mo/yr
|
- | |
| 07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $249 | $1,751 |
$171
1,428
kWh
|
$78
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $22,771 | $85,085 |
$17,154
142,953
kWh
|
$3,289
-
kW-mo/yr
|
$2,327
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs