Assessment Year 2024
Principal Product Container Lids
NAICS 332431: Metal Can Manufacturing
SIC 3411: Metal Cans
Sales Range $50
M
to 100
M
# of Employees 120
Plant Area 200,000
ft2
Annual Production 1,235,000,000
units
Production Hrs. Annual 6,240
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $251,836 2,759,244
kWh
Electricity Demand $90,627 7,796
kW-mo/yr
Electricity Fees $21,478 -
Natural Gas $50,117 7,389
MMBtu
TOTAL YEARLY COSTS $414,058
RECOMMENDED SAVINGS* $382,333 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $26,380

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.9114: Use solar heat to make electricty $341,931 $2,037,172 $197,262
2,167,719
kWh
$144,669
-
kW-mo/yr
-
02 2.4221: Install compressor air intakes in coolest locations $3,300 $1,110 $2,649
29,112
kWh
$651
-
kW-mo/yr
-
03 2.4226: Use / purchase optimum sized compressor $13,885 $54,145 $11,148
122,501
kWh
$2,737
-
kW-mo/yr
-
04 2.4111: Utilize energy-efficient belts and other improved mechanisms $384 $338 $384
4,219
kWh
- -
05 2.2515: Use optimum thickness insulation $17,140 $38,685 $1,308
14,378
kWh
$11,676
-
kW-mo/yr
$4,156
-
MMBtu
06 2.7142: Utilize higher efficiency lamps and/or ballasts $4,336 $6,391 $3,253
35,747
kWh
$1,084
-
kW-mo/yr
-
07 2.6211: Conserve energy by efficient use of vending machines $137 $495 $114
1,250
kWh
$24
-
kW-mo/yr
-
08 2.7441: Replace broken windows and/or window sash $1,219 $3,519 $55
609
kWh
$494
-
kW-mo/yr
$669
-
MMBtu
TOTAL RECOMMENDED $382,333 $2,141,854 $216,174
2,375,535
kWh
$161,334
-
kW-mo/yr
$4,826
-
MMBtu
TOTAL IMPLEMENTED $26,380 $50,043 $7,650
84,065
kWh
$13,904
-
kW-mo/yr
$4,826
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs