Assessment Year | 2009 |
---|---|
Principal Product | Architectural Paint Colorant |
NAICS | 325510: Paint and Coating Manufacturing |
SIC | 2851: Paints, Varnishes, Lacquers, Enamels, and Allied Products |
Sales Range | $100 M to 500M |
# of Employees | 68 |
Plant Area |
84,300
ft2
|
Annual Production | 1,750
Tgal
|
Production Hrs. Annual | 8,232
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $293,302 | 3,321,400 |
kWh
|
$0.088 |
Electricity Demand | $51,607 | 9,396 |
kW-mo/yr
|
$5.49 |
Natural Gas | $82,367 | 8,818 |
MMBtu
|
$9.34 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $107,049 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $91,297 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $12,002 | $21,920 |
$12,866
146,200
kWh
|
$1,169
-
kW-mo/yr
|
- | $(-1,890.0) | $(-143.0) | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $13,423 | $40,720 |
$14,604
165,957
kWh
|
$1,329
-
kW-mo/yr
|
- | $366 | $(-2,876.0) | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,329 | - |
$2,318
26,342
kWh
|
$209
-
kW-mo/yr
|
- | - | $(-198.0) | |
04 | 2.7135: Install occupancy sensors | $381 | $453 |
$298
3,391
kWh
|
$83
-
kW-mo/yr
|
- | - | - | |
05 | 2.4133: Use most efficient type of electric motors | $60,460 | $63,169 |
$56,123
637,761
kWh
|
$4,337
-
kW-mo/yr
|
- | - | - | |
06 | 2.4224: Upgrade controls on compressors | $11,716 | $148 |
$15,416
175,177
kWh
|
$(-3,700.0)
-
kW-mo/yr
|
- | - | - | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,189 | $889 |
$1,189
13,510
kWh
|
- | - | - | - | |
08 | 2.623: Equipment automation | $5,034 | - | - | - |
$5,034
-
MMBtu
|
- | - | |
09 | 2.6211: Conserve energy by efficient use of vending machines | $515 | - |
$317
3,600
kWh
|
$198
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $107,049 | $127,299 |
$103,131
1,171,938
kWh
|
$3,625
-
kW-mo/yr
|
$5,034
-
MMBtu
|
$(-1,524.0) | $(-3,217.0) | ||
TOTAL IMPLEMENTED | $91,297 | $86,579 |
$86,209
979,639
kWh
|
$2,087
-
kW-mo/yr
|
$5,034
-
MMBtu
|
$(-1,890.0) | $(-143.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs