Assessment Year | 2008 |
---|---|
Principal Product | Flexible Healthcare Packaging |
NAICS | 326112: Plastics Packaging Film and Sheet (including Laminated) Manufacturing |
SIC | 2671: Packaging Paper and Plastics Film, Coated and Laminated |
Sales Range | $50 M to 100M |
# of Employees | 300 |
Plant Area |
175,000
ft2
|
Annual Production | 40,000,000
pieces
|
Production Hrs. Annual | 8,712
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,027,938 | 14,832,931 |
kWh
|
$0.069 |
Electricity Demand | $147,083 | 24,886 |
kW-mo/yr
|
$5.91 |
Electricity Fees | $3,208 | - |
|
- |
Natural Gas | $174,377 | 14,930 |
MMBtu
|
$11.68 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $140,387 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $24,717 | $87,000 |
$34,497
499,951
kWh
|
$4,052
-
kW-mo/yr
|
- | $(-9,188.0) | $(-4,644.0) | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $12,067 | $43,816 |
$8,275
119,957
kWh
|
$1,445
-
kW-mo/yr
|
- | $428 | $1,919 | |
03 | 2.7135: Install occupancy sensors | $1,046 | $2,392 |
$749
10,857
kWh
|
$297
-
kW-mo/yr
|
- | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $60 | $38 |
$31
444
kWh
|
$12
-
kW-mo/yr
|
- | $24 | $(-7.0) | |
05 | 2.4133: Use most efficient type of electric motors | $13,149 | $40,438 |
$11,756
170,926
kWh
|
$1,393
-
kW-mo/yr
|
- | - | - | |
06 | 2.4224: Upgrade controls on compressors | $33,062 | - |
$33,062
479,160
kWh
|
- | - | - | - | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,084 | - |
$2,084
30,200
kWh
|
- | - | - | - | |
08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $25,247 | $13,262 |
$25,247
365,904
kWh
|
- | - | - | - | |
09 | 2.4239: Eliminate or reduce compressed air usage | $17,489 | $7,260 |
$17,489
253,467
kWh
|
- | - | - | - | |
10 | 2.7314: Reduce ventilation air | $7,098 | - |
$7,098
102,869
kWh
|
- | - | - | - | |
11 | 2.7261: Install timers and/or thermostats | $4,368 | - | - | - |
$4,368
-
MMBtu
|
- | - | |
TOTAL RECOMMENDED | $140,387 | $194,206 |
$140,288
2,033,735
kWh
|
$7,199
-
kW-mo/yr
|
$4,368
-
MMBtu
|
$(-8,736.0) | $(-2,732.0) | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs