Assessment Year | 2009 |
---|---|
Principal Product | motor Homes |
NAICS | 336213: Motor Home Manufacturing |
SIC | 3716: Motor Homes |
Sales Range | greater than $500 M |
# of Employees | 2,250 |
Plant Area |
2,000,000
ft2
|
Annual Production | 6,400
units
|
Production Hrs. Annual | 2,375
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,457,056 | 26,425,948 |
kWh
|
$0.055 |
Natural Gas | $1,766,322 | 185,246 |
MMBtu
|
$9.54 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $188,534 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $159,121 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Increase in Production Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $78,974 | $329,643 |
$36,372
1,082,723
kWh
|
$42,602
-
kW-mo/yr
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $34,846 | $114,679 |
$15,564
646,605
kWh
|
$19,282
-
kW-mo/yr
|
- | - | |
03 | 2.7144: Install spectral reflectors / delamp | $2,046 | $228 |
$2,046
25,433
kWh
|
- | - | - | |
04 | 2.4226: Use / purchase optimum sized compressor | $13,962 | $2,381 |
$13,962
416,781
kWh
|
- | - | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,135 | $31,226 |
$6,135
148,814
kWh
|
- | - | - | |
06 | 2.4239: Eliminate or reduce compressed air usage | $1,380 | $626 |
$1,380
41,175
kWh
|
- | - | - | |
07 | 2.4239: Eliminate or reduce compressed air usage | $5,416 | $500 |
$5,416
161,774
kWh
|
- | - | - | |
08 | 2.2437: Recover waste heat from equipment | $4,190 | $1,045 | - | - |
$4,190
-
MMBtu
|
- | |
09 | 2.4221: Install compressor air intakes in coolest locations | $986 | $216 |
$986
26,927
kWh
|
- | - | - | |
10 | 2.7316: Centralize control of exhaust fans to ensure their shutdown, or establish program to ensure manual shutdown | $7,336 | $7,337 |
$562
16,785
kWh
|
- |
$6,774
-
MMBtu
|
- | |
11 | 2.7316: Centralize control of exhaust fans to ensure their shutdown, or establish program to ensure manual shutdown | $3,292 | $2,000 | - | - |
$3,292
-
MMBtu
|
- | |
12 | 2.4322: Use or replace with energy efficient substitutes | $16,602 | $60,000 |
$4,774
142,500
kWh
|
$11,828
-
kW-mo/yr
|
- | - | |
13 | 2.2511: Insulate bare equipment | $5,401 | $10,500 | - | - |
$5,401
-
MMBtu
|
- | |
14 | 2.7447: Install vinyl strip / high speed / air curtain doors | $6,644 | $15,500 | - | - |
$6,644
-
MMBtu
|
- | |
15 | 3.1191: Change procedures / equipment / operating conditions | $1,324 | $10,000 | - | - |
$827
-
MMBtu
|
$497 | |
TOTAL RECOMMENDED | $188,534 | $585,881 |
$87,197
2,709,517
kWh
|
$73,712
-
kW-mo/yr
|
$27,128
-
MMBtu
|
$497 | ||
TOTAL IMPLEMENTED | $159,121 | $540,044 |
$81,219
2,530,958
kWh
|
$73,712
-
kW-mo/yr
|
$4,190
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Increase in Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs