Assessment Year 2009
Principal Product motor Homes
NAICS 336213: Motor Home Manufacturing
SIC 3716: Motor Homes
Sales Range greater than $500
M
# of Employees 2,250
Plant Area 2,000,000
ft2
Annual Production 6,400
units
Production Hrs. Annual 2,375
hrs
Location (State) Iowa

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,457,056 26,425,948
kWh
Natural Gas $1,766,322 185,246
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $188,534 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $159,121

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Increase in Production Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $78,974 $329,643 $36,372
1,082,723
kWh
$42,602
-
kW-mo/yr
- -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $34,846 $114,679 $15,564
646,605
kWh
$19,282
-
kW-mo/yr
- -
03 2.7144: Install spectral reflectors / delamp $2,046 $228 $2,046
25,433
kWh
- - -
04 2.4226: Use / purchase optimum sized compressor $13,962 $2,381 $13,962
416,781
kWh
- - -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $6,135 $31,226 $6,135
148,814
kWh
- - -
06 2.4239: Eliminate or reduce compressed air usage $1,380 $626 $1,380
41,175
kWh
- - -
07 2.4239: Eliminate or reduce compressed air usage $5,416 $500 $5,416
161,774
kWh
- - -
08 2.2437: Recover waste heat from equipment $4,190 $1,045 - - $4,190
-
MMBtu
-
09 2.4221: Install compressor air intakes in coolest locations $986 $216 $986
26,927
kWh
- - -
10 2.7316: Centralize control of exhaust fans to ensure their shutdown, or establish program to ensure manual shutdown $7,336 $7,337 $562
16,785
kWh
- $6,774
-
MMBtu
-
11 2.7316: Centralize control of exhaust fans to ensure their shutdown, or establish program to ensure manual shutdown $3,292 $2,000 - - $3,292
-
MMBtu
-
12 2.4322: Use or replace with energy efficient substitutes $16,602 $60,000 $4,774
142,500
kWh
$11,828
-
kW-mo/yr
- -
13 2.2511: Insulate bare equipment $5,401 $10,500 - - $5,401
-
MMBtu
-
14 2.7447: Install vinyl strip / high speed / air curtain doors $6,644 $15,500 - - $6,644
-
MMBtu
-
15 3.1191: Change procedures / equipment / operating conditions $1,324 $10,000 - - $827
-
MMBtu
$497
TOTAL RECOMMENDED $188,534 $585,881 $87,197
2,709,517
kWh
$73,712
-
kW-mo/yr
$27,128
-
MMBtu
$497
TOTAL IMPLEMENTED $159,121 $540,044 $81,219
2,530,958
kWh
$73,712
-
kW-mo/yr
$4,190
-
MMBtu
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Increase in Production Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs