Assessment Year 2006
Principal Product Printed Material
NAICS 323111: Commercial Printing (except Screen and Books)
SIC 2752: Commercial Printing, Lithographic
Sales Range $10
M
to 50
M
# of Employees 700
Plant Area 200,000
ft2
Annual Production 15
ton
Production Hrs. Annual 8,160
hrs
Location (State) Minnesota

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $250,029 5,975,120
kWh
Electricity Demand $126,013 1,400
kW-mo/yr
Natural Gas $277,643 26,620
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $57,991 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,532 $1,864 $2,788
67,900
kWh
$744
-
kW-mo/yr
-
02 2.4221: Install compressor air intakes in coolest locations $3,097 $900 $2,273
55,412
kWh
$824
-
kW-mo/yr
-
03 2.7142: Utilize higher efficiency lamps and/or ballasts $21,029 $32,168 $17,348
422,076
kWh
$3,681
-
kW-mo/yr
-
04 2.7142: Utilize higher efficiency lamps and/or ballasts $8,976 $16,842 $7,077
172,176
kWh
$1,899
-
kW-mo/yr
-
05 2.4133: Use most efficient type of electric motors $936 - $738
17,952
kWh
$198
-
kW-mo/yr
-
06 2.2437: Recover waste heat from equipment $1,212 $553 - - $1,212
-
MMBtu
07 2.6231: Utilize controls to operate equipment only when needed $2,373 $2,000 $2,373
57,732
kWh
- -
08 2.5123: Reduce fluid flow rates $16,836 $1,580 $16,836
409,632
kWh
- -
TOTAL RECOMMENDED $57,991 $55,907 $49,433
1,202,880
kWh
$7,346
-
kW-mo/yr
$1,212
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs