| Assessment Year | 2006 |
|---|---|
| Principal Product | Agricultural Equipment |
| NAICS | 333111: Farm Machinery and Equipment Manufacturing |
| SIC | 3523: Farm Machinery and Equipment |
| Sales Range | $10 M to 50M |
| # of Employees | 140 |
| Plant Area |
140,000
ft2
|
| Annual Production | 3,000
ton
|
| Production Hrs. Annual | 3,250
hrs
|
| Location (State) | Nebraska |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $50,952 | 1,824,960 |
kWh
|
$0.028 |
| Electricity Demand | $67,781 | 6,720 |
kW-mo/yr
|
$10.09 |
| Natural Gas | $178,900 | 17,490 |
MMBtu
|
$10.23 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $15,795 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $6,364 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,991 | $410 |
$1,326
49,262
kWh
|
$985
-
kW-mo/yr
|
- | $(-320.0) | |
| 02 | 2.4221: Install compressor air intakes in coolest locations | $186 | $198 |
$79
2,461
kWh
|
$107
-
kW-mo/yr
|
- | - | |
| 03 | 2.4133: Use most efficient type of electric motors | $136 | $89 |
$69
2,589
kWh
|
$67
-
kW-mo/yr
|
- | - | |
| 04 | 2.2525: Eliminate cooling of process streams which subsequently must be heated and vice versa | $3,433 | $1,735 | - | - |
$3,433
-
MMBtu
|
- | |
| 05 | 2.7243: Improve air circulation with destratification fans / other methods | $3,668 | $12,865 | - | - |
$3,668
-
MMBtu
|
- | |
| 06 | 2.2511: Insulate bare equipment | $5,577 | $349 | - | - |
$5,577
-
MMBtu
|
- | |
| 07 | 2.7442: Keep doors and windows shut when not on use | $804 | $600 | - | - |
$804
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $15,795 | $16,246 |
$1,474
54,312
kWh
|
$1,159
-
kW-mo/yr
|
$13,482
-
MMBtu
|
$(-320.0) | ||
| TOTAL IMPLEMENTED | $6,364 | $2,834 |
$1,395
51,851
kWh
|
$1,052
-
kW-mo/yr
|
$4,237
-
MMBtu
|
$(-320.0) | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs