Assessment Year | 1995 |
---|---|
Principal Product | car caddies and trailors |
NAICS |
n/a
|
SIC | 3799: Transportation Equipment, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 300 |
Plant Area |
200,000
ft2
|
Annual Production | 7,000
pieces
|
Production Hrs. Annual | 5,226
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $122,135 | 2,847,304 |
kWh
|
$0.043 |
Natural Gas | $49,019 | 14,026 |
MMBtu
|
$3.49 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $64,617 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $56,285 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Solid Waste (haz) Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $28,462 | $66,000 |
$54,595
1,272,861
kWh
|
$(-26,133.0)
-
MMBtu
|
- | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,093 | $400 |
$3,093
72,098
kWh
|
- | - | - | |
03 | 2.4221: Install compressor air intakes in coolest locations | $561 | $25 |
$561
13,189
kWh
|
- | - | - | |
04 | 2.7135: Install occupancy sensors | $2,771 | $3,555 |
$2,771
64,478
kWh
|
- | - | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,384 | $520 |
$1,384
32,239
kWh
|
- | - | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $13,382 | $51,892 |
$13,382
312,134
kWh
|
- | - | - | |
07 | 2.7444: Close holes and openings in building such as broken windows | $258 | $392 | - |
$258
-
MMBtu
|
- | - | |
08 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $11,090 | $7,400 | - | - |
$11,090
-
lb
|
- | |
09 | 3.1191: Change procedures / equipment / operating conditions | $3,431 | $3,614 | - | - | - |
$3,431
-
lb
|
|
10 | 3.1191: Change procedures / equipment / operating conditions | $185 | $300 | - | - |
$185
-
lb
|
- | |
TOTAL RECOMMENDED | $64,617 | $134,098 |
$75,786
1,766,999
kWh
|
$(-25,875.0)
-
MMBtu
|
$11,275
-
lb
|
$3,431
-
lb
|
||
TOTAL IMPLEMENTED | $56,285 | $126,084 |
$71,070
1,657,093
kWh
|
$(-25,875.0)
-
MMBtu
|
$11,090
-
lb
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Solid Waste (haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs