Assessment Year | 1984 |
---|---|
Principal Product | STARTER RING GEARS |
NAICS |
n/a
|
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $5 M to 10M |
# of Employees | 84 |
Plant Area |
n/a
|
Annual Production | 1,000,000
pieces
|
Production Hrs. Annual | 7,200
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $122,653 | 1,716,589 |
kWh
|
$0.071 |
Natural Gas | $135,961 | 21,528 |
MMBtu
|
$6.32 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $37,791 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $37,791 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 3.4157: Replace water cooling on processes with air cooling | $28,921 | $935 |
$1,073
9,672
kWh
|
$6,806
-
MMBtu
|
$21,042 | |
02 | 2.2414: Use waste heat from hot flue gases to preheat | $6,060 | $10,000 | - |
$6,060
-
MMBtu
|
- | |
03 | 2.7111: Reduce illumination to minimum necessary levels | $2,810 | $384 |
$3,191
77,960
kWh
|
$(-381.0)
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $37,791 | $11,319 |
$4,264
87,632
kWh
|
$12,485
-
MMBtu
|
$21,042 | ||
TOTAL IMPLEMENTED | $37,791 | $11,319 |
$4,264
87,632
kWh
|
$12,485
-
MMBtu
|
$21,042 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs