Assessment Year 1984
Principal Product STARTER RING GEARS
NAICS
n/a
SIC 3714: Motor Vehicle Parts and Accessories
Sales Range $5
M
to 10
M
# of Employees 84
Plant Area
n/a
Annual Production 1,000,000
pieces
Production Hrs. Annual 7,200
hrs
Location (State) Ohio

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $122,653 1,716,589
kWh
Natural Gas $135,961 21,528
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $37,791 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $37,791

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
01 3.4157: Replace water cooling on processes with air cooling $28,921 $935 $1,073
9,672
kWh
$6,806
-
MMBtu
$21,042
02 2.2414: Use waste heat from hot flue gases to preheat $6,060 $10,000 - $6,060
-
MMBtu
-
03 2.7111: Reduce illumination to minimum necessary levels $2,810 $384 $3,191
77,960
kWh
$(-381.0)
-
MMBtu
-
TOTAL RECOMMENDED $37,791 $11,319 $4,264
87,632
kWh
$12,485
-
MMBtu
$21,042
TOTAL IMPLEMENTED $37,791 $11,319 $4,264
87,632
kWh
$12,485
-
MMBtu
$21,042
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs