ITAC Assessment: IA0095
ITAC logo
ITAC Assessment: IA0095
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1994
Principal Product catalogues and brochures
NAICS
n/a
SIC 2721: Periodicals: Publishing, or Publishing and Printing
Sales Range $10
M
to 50
M
# of Employees 140
Plant Area 150,000
ft2
Annual Production 8,700,000
lb
Production Hrs. Annual 7,488
hrs
Location (State) Iowa

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $187,142 4,207,796
kWh
Natural Gas $35,962 8,025
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $23,591 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $4,622

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.6218: Turn off equipment when not in use $4,503 $1,050 $4,503
101,114
kWh
-
02 2.4133: Use most efficient type of electric motors $4,679 $4,728 $4,679
105,217
kWh
-
03 2.7142: Utilize higher efficiency lamps and/or ballasts $4,130 $917 $4,130
92,907
kWh
-
04 2.7135: Install occupancy sensors $876 $1,155 $876
19,637
kWh
-
05 2.7142: Utilize higher efficiency lamps and/or ballasts $492 $1,596 $492
11,137
kWh
-
06 2.5121: Redesign flow to minimize mass transfer length $3,961 $14,000 $3,961
89,097
kWh
-
07 2.4221: Install compressor air intakes in coolest locations $2,345 $170 $2,345
52,755
kWh
-
08 2.7261: Install timers and/or thermostats $1,407 $1,950 $685
15,533
kWh
$722
-
MMBtu
09 2.4239: Eliminate or reduce compressed air usage $769 $1,750 $769
17,292
kWh
-
10 2.7491: Insulate glazing, walls, ceilings, and roofs $282 $276 $282
12,603
kWh
-
11 2.7228: Avoid introducing hot, humid, or dirty air into hvac system $147 $75 $147
3,224
kWh
-
TOTAL RECOMMENDED $23,591 $27,667 $22,869
520,516
kWh
$722
-
MMBtu
TOTAL IMPLEMENTED $4,622 $2,513 $4,622
104,044
kWh
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs