| Assessment Year | 1993 |
|---|---|
| Principal Product | RADIOS, MONITORS, RECVRS |
| NAICS |
n/a
|
| SIC | 3651: Household Audio and Video Equipment |
| Sales Range | $5 M to 10M |
| # of Employees | 150 |
| Plant Area |
n/a
|
| Annual Production | 58,000
pieces
|
| Production Hrs. Annual | 2,210
hrs
|
| Location (State) | Nebraska |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $88,979 | 1,358,148 |
kWh
|
$0.066 |
| Natural Gas | $32,110 | 7,620 |
MMBtu
|
$4.21 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $20,184 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $13,285 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7261: Install timers and/or thermostats | $9,150 | $37 |
$1,862
28,429
kWh
|
$7,288
-
MMBtu
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,786 | - |
$2,171
33,118
kWh
|
- | $(-385.0) | |
| 03 | 2.7111: Reduce illumination to minimum necessary levels | $2,131 | $790 |
$2,131
32,532
kWh
|
- | - | |
| 04 | 2.7122: Disconnect ballasts | $1,389 | $4,530 |
$1,389
21,102
kWh
|
- | - | |
| 05 | 2.7135: Install occupancy sensors | $752 | $1,404 |
$752
11,430
kWh
|
- | - | |
| 06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,484 | $25 |
$1,484
22,567
kWh
|
- | - | |
| 07 | 2.4221: Install compressor air intakes in coolest locations | $713 | $360 |
$713
10,844
kWh
|
- | - | |
| 08 | 2.2437: Recover waste heat from equipment | $1,889 | $4,427 |
$(-288.0)
(-4,396)
kWh
|
$2,177
-
MMBtu
|
- | |
| 09 | 2.3132: Recharge batteries on during off-peak demand periods | $865 | - |
$865
-
kWh
|
- | - | |
| 10 | 2.4133: Use most efficient type of electric motors | $25 | $50 |
$25
293
kWh
|
- | - | |
| TOTAL RECOMMENDED | $20,184 | $11,623 |
$11,104
155,919
kWh
|
$9,465
-
MMBtu
|
$(-385.0) | ||
| TOTAL IMPLEMENTED | $13,285 | $62 |
$6,382
84,114
kWh
|
$7,288
-
MMBtu
|
$(-385.0) | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs