ITAC Assessment: IA0042
ITAC logo
ITAC Assessment: IA0042
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1992
Principal Product GYPSUM PRODUCTS
NAICS
n/a
SIC 3275: Gypsum Products
Sales Range $1
M
to 5
M
# of Employees 43
Plant Area
n/a
Annual Production 550,000
ton
Production Hrs. Annual 8,736
hrs
Location (State) Iowa

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $237,185 5,390,973
kWh
Natural Gas $817,161 351,908
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $45,914 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $30,707

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
01 2.1213: Direct warmest air to combustion intake $25,018 $6,000 - $25,018
-
MMBtu
-
02 2.2441: Preheat boiler makeup water with waste process heat $11,110 $3,925 - $11,110
-
MMBtu
-
03 2.1213: Direct warmest air to combustion intake $939 $250 - $939
-
MMBtu
-
04 2.4111: Utilize energy-efficient belts and other improved mechanisms $3,478 $9,905 $3,478
79,132
kWh
- -
05 2.4221: Install compressor air intakes in coolest locations $1,328 $150 $1,328
30,188
kWh
- -
06 2.6232: Install set-back timers $3,181 $2,376 $3,181
72,392
kWh
- -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $619 $1,575 $619
14,068
kWh
- -
08 2.7142: Utilize higher efficiency lamps and/or ballasts $241 $185 $426
9,672
kWh
- $(-185.0)
TOTAL RECOMMENDED $45,914 $24,366 $9,032
205,452
kWh
$37,067
-
MMBtu
$(-185.0)
TOTAL IMPLEMENTED $30,707 $8,961 $4,935
112,252
kWh
$25,957
-
MMBtu
$(-185.0)
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs