Assessment Year 2011
Principal Product Teabags
NAICS 311920: Coffee and Tea Manufacturing
SIC 2099: Food Preparations, Not Elsewhere Classified
Sales Range $50
M
to 100
M
# of Employees 195
Plant Area 231,644
ft2
Annual Production 32,000,000
lb
Production Hrs. Annual 7,500
hrs
Location (State) Georgia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $253,268 4,985,600
kWh
Electricity Demand $181,429 12,167
kW-mo/yr
Electricity Fees $30,920 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $164,328 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $50,130

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Ancillary Material Cost Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $4,890 $44,900 $3,330
65,500
kWh
$1,560
-
kW-mo/yr
-
02 2.7135: Install occupancy sensors $4,290 $210 $4,290
84,400
kWh
- -
03 2.7233: Use properly designed and sized hvac equipment $57,100 $361,600 $17,200
339,000
kWh
$22,500
-
kW-mo/yr
$17,400
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $11,400 $600 $7,820
154,000
kWh
$3,580
-
kW-mo/yr
-
05 2.4239: Eliminate or reduce compressed air usage $16,610 $14,000 $11,300
223,000
kWh
$5,310
-
kW-mo/yr
-
06 2.4239: Eliminate or reduce compressed air usage $2,894 $43,550 $1,970
38,800
kWh
$924
-
kW-mo/yr
-
07 2.6231: Utilize controls to operate equipment only when needed $29,550 $2,000 $20,100
395,000
kWh
$9,450
-
kW-mo/yr
-
08 2.4224: Upgrade controls on compressors $31,010 $160,650 $21,900
432,000
kWh
$9,110
-
kW-mo/yr
-
09 2.3212: Optimize plant power factor $6,584 $37,790 $3,860
76,000
kWh
$2,724
-
kW-mo/yr
-
TOTAL RECOMMENDED $164,328 $665,300 $91,770
1,807,700
kWh
$55,158
-
kW-mo/yr
$17,400
TOTAL IMPLEMENTED $50,130 $47,710 $35,540
698,900
kWh
$14,590
-
kW-mo/yr
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs