Assessment Year | 1999 |
---|---|
Principal Product | Metal Gratings |
NAICS |
n/a
|
SIC | 3499: Fabricated Metal Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 23 |
Plant Area |
25,000
ft2
|
Annual Production | 6,000
ton
|
Production Hrs. Annual | 3,000
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $7,842 | 128,664 |
kWh
|
$0.061 |
Electricity Demand | $4,445 | 285 |
kW-mo/yr
|
$15.60 |
Electricity Fees | $4,713 | - |
|
- |
Natural Gas | $6,153 | 1,030 |
MMBtu
|
$5.97 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,416 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,521 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Disposal Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.8113: Purchase gas directly from a contract gas supplier | $742 | - | - | - | - | - | - | $742 | |
02 | 3.4155: Meter waste water | $1,276 | $500 | - | - | - | - |
$1,276
-
Tgal
|
- | |
03 | 2.8123: Pay utility bills on time | $1,258 | - | - | - | - | - | - | $1,258 | |
04 | 2.3132: Recharge batteries on during off-peak demand periods | $1,468 | $200 | - |
$1,385
-
kW-mo/yr
|
$83 | - | - | - | |
05 | 3.6192: Use a less expensive method of waste removal | $216 | - | - | - | - | - | - | $216 | |
06 | 2.7261: Install timers and/or thermostats | $777 | $600 |
$57
879
kWh
|
- | - |
$720
-
MMBtu
|
- | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,316 | $2,398 |
$821
13,482
kWh
|
$421
-
kW-mo/yr
|
$74 | - | - | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,363 | $3,000 |
$851
14,068
kWh
|
$435
-
kW-mo/yr
|
$77 | - | - | - | |
TOTAL RECOMMENDED | $8,416 | $6,698 |
$1,729
28,429
kWh
|
$2,241
-
kW-mo/yr
|
$234 |
$720
-
MMBtu
|
$1,276
-
Tgal
|
$2,216 | ||
TOTAL IMPLEMENTED | $5,521 | $1,300 |
$57
879
kWh
|
$1,385
-
kW-mo/yr
|
$83 |
$720
-
MMBtu
|
$1,276
-
Tgal
|
$2,000 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Disposal Savings | Administrative Changes Savings |