Assessment Year | 2005 |
---|---|
Principal Product | Dental Drill Bits |
NAICS | 339114: Dental Equipment and Supplies Manufacturing |
SIC | 3843: Dental Equipment and Supplies |
Sales Range | $5 M to 10M |
# of Employees | 420 |
Plant Area |
85,000
ft2
|
Annual Production | 5,000,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $150,750 | 3,530,445 |
kWh
|
$0.043 |
Electricity Demand | $80,859 | 7,990 |
kW-mo/yr
|
$10.12 |
Electricity Fees | $20,843 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $44,568 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $35,171 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4314: Use synthetic lubricant | $600 | - |
$406
9,512
kWh
|
$194
-
kW-mo/yr
|
- | - | |
02 | 2.7261: Install timers and/or thermostats | $20,280 | $10,000 |
$20,280
609,120
kWh
|
- | - | - | |
03 | 2.4221: Install compressor air intakes in coolest locations | $469 | $400 |
$340
7,920
kWh
|
$129
-
kW-mo/yr
|
- | - | |
04 | 2.2628: Utilize a less expensive cooling method | $283 | $300 |
$192
4,500
kWh
|
$91
-
kW-mo/yr
|
- | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $195 | $221 |
$100
2,340
kWh
|
$95
-
kW-mo/yr
|
- | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $14,096 | $24,867 |
$9,505
222,591
kWh
|
$4,591
-
kW-mo/yr
|
- | - | |
07 | 2.8112: Combine utility meters | $3,889 | $4,550 | - | - | - | $3,889 | |
08 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,393 | $3,500 |
$945
22,125
kWh
|
$448
-
kW-mo/yr
|
- | - | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,363 | $8,720 |
$1,297
6,815
kWh
|
- | $2,066 | - | |
TOTAL RECOMMENDED | $44,568 | $52,558 |
$33,065
884,923
kWh
|
$5,548
-
kW-mo/yr
|
$2,066 | $3,889 | ||
TOTAL IMPLEMENTED | $35,171 | $35,088 |
$30,291
843,563
kWh
|
$4,880
-
kW-mo/yr
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs