Assessment Year | 1993 |
---|---|
Principal Product | Windows and Patio Doors |
NAICS |
n/a
|
SIC | 2431: Millwork |
Sales Range | $50 M to 100M |
# of Employees | 570 |
Plant Area |
550,000
ft2
|
Annual Production | 450,000
pieces
|
Production Hrs. Annual | 4,960
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $491,735 | 7,479,484 |
kWh
|
$0.066 |
Natural Gas | $42,544 | 8,822 |
MMBtu
|
$4.82 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $62,525 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $40,610 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,700 | $4,160 |
$3,700
56,272
kWh
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,470 | $18,550 |
$5,470
83,236
kWh
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,950 | $10,500 |
$4,950
75,322
kWh
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $535 | $900 |
$535
8,206
kWh
|
|
05 | 2.7135: Install occupancy sensors | $2,260 | $1,960 |
$2,260
34,584
kWh
|
|
06 | 2.7134: Use photocell controls | $800 | $700 |
$800
12,309
kWh
|
|
07 | 2.7134: Use photocell controls | $130 | $70 |
$130
2,052
kWh
|
|
08 | 2.4221: Install compressor air intakes in coolest locations | $445 | $370 |
$445
6,741
kWh
|
|
09 | 2.6212: Turn off equipment during breaks, reduce operating time | $2,165 | $1,000 |
$2,165
32,825
kWh
|
|
10 | 2.4133: Use most efficient type of electric motors | $5,280 | $23,650 |
$5,280
80,598
kWh
|
|
11 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $7,185 | $14,200 |
$7,185
109,320
kWh
|
|
12 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $630 | - |
$630
9,672
kWh
|
|
13 | 2.6232: Install set-back timers | $9,555 | $31,200 |
$9,555
145,369
kWh
|
|
14 | 2.6212: Turn off equipment during breaks, reduce operating time | $19,420 | $1,000 |
$19,420
295,721
kWh
|
|
TOTAL RECOMMENDED | $62,525 | $108,260 |
$62,525
952,227
kWh
|
||
TOTAL IMPLEMENTED | $40,610 | $51,620 |
$40,610
618,405
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs