ITAC Assessment: GT0496
ITAC logo
ITAC Assessment: GT0496
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1993
Principal Product Finished Cast-Metal Products
NAICS
n/a
SIC 3498: Fabricated Pipe and Pipe Fittings
Sales Range $1
M
to 5
M
# of Employees 12
Plant Area 25,000
ft2
Annual Production 480,000
lb
Production Hrs. Annual 2,500
hrs
Location (State) Georgia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $20,157 167,937
kWh
Natural Gas $15,175 2,622
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $4,090 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $1,890

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,890 $750 $1,890
15,826
kWh
02 2.4226: Use / purchase optimum sized compressor $2,200 $7,100 $2,200
16,999
kWh
TOTAL RECOMMENDED $4,090 $7,850 $4,090
32,825
kWh
TOTAL IMPLEMENTED $1,890 $750 $1,890
15,826
kWh
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs