| Assessment Year | 1992 |
|---|---|
| Principal Product | ROLLED CLOTH |
| NAICS |
n/a
|
| SIC | 2221: Broadwoven Fabric Mills, Manmade Fiber and Silk |
| Sales Range | $10 M to 50M |
| # of Employees | 320 |
| Plant Area |
n/a
|
| Annual Production | 11,000,000
lb
|
| Production Hrs. Annual | 8,600
hrs
|
| Location (State) | South Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $1,886,689 | 55,194,022 |
kWh
|
$0.034 |
| Natural Gas | $129,098 | 54,513 |
MMBtu
|
$2.37 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $79,444 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $79,444 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.2135: Repair and eliminate steam leaks | $764 | $200 | - |
$764
-
MMBtu
|
- | |
| 02 | 2.2441: Preheat boiler makeup water with waste process heat | $4,070 | $13,000 | - |
$4,070
-
MMBtu
|
- | |
| 03 | 2.4133: Use most efficient type of electric motors | $520 | $5,020 |
$520
14,947
kWh
|
- | - | |
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $12,230 | $67,220 |
$12,230
357,562
kWh
|
- | - | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,570 | - |
$1,570
45,721
kWh
|
- | - | |
| 06 | 2.4221: Install compressor air intakes in coolest locations | $7,700 | $900 |
$7,700
225,088
kWh
|
- | - | |
| 07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $26,330 | - |
$26,330
769,930
kWh
|
- | - | |
| 08 | 2.6232: Install set-back timers | $2,120 | $1,010 |
$2,120
61,841
kWh
|
- | - | |
| 09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $24,140 | $93,920 |
$24,329
711,606
kWh
|
- | $(-189.0) | |
| TOTAL RECOMMENDED | $79,444 | $181,270 |
$74,799
2,186,695
kWh
|
$4,834
-
MMBtu
|
$(-189.0) | ||
| TOTAL IMPLEMENTED | $79,444 | $181,270 |
$74,799
2,186,695
kWh
|
$4,834
-
MMBtu
|
$(-189.0) | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs