Assessment Year 1992
Principal Product ROLLED CLOTH
NAICS
n/a
SIC 2221: Broadwoven Fabric Mills, Manmade Fiber and Silk
Sales Range $10
M
to 50
M
# of Employees 320
Plant Area
n/a
Annual Production 11,000,000
lb
Production Hrs. Annual 8,600
hrs
Location (State) South Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,886,689 55,194,022
kWh
Natural Gas $129,098 54,513
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $79,444 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $79,444

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
01 2.2135: Repair and eliminate steam leaks $764 $200 - $764
-
MMBtu
-
02 2.2441: Preheat boiler makeup water with waste process heat $4,070 $13,000 - $4,070
-
MMBtu
-
03 2.4133: Use most efficient type of electric motors $520 $5,020 $520
14,947
kWh
- -
04 2.4111: Utilize energy-efficient belts and other improved mechanisms $12,230 $67,220 $12,230
357,562
kWh
- -
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,570 - $1,570
45,721
kWh
- -
06 2.4221: Install compressor air intakes in coolest locations $7,700 $900 $7,700
225,088
kWh
- -
07 2.4231: Reduce the pressure of compressed air to the minimum required $26,330 - $26,330
769,930
kWh
- -
08 2.6232: Install set-back timers $2,120 $1,010 $2,120
61,841
kWh
- -
09 2.7142: Utilize higher efficiency lamps and/or ballasts $24,140 $93,920 $24,329
711,606
kWh
- $(-189.0)
TOTAL RECOMMENDED $79,444 $181,270 $74,799
2,186,695
kWh
$4,834
-
MMBtu
$(-189.0)
TOTAL IMPLEMENTED $79,444 $181,270 $74,799
2,186,695
kWh
$4,834
-
MMBtu
$(-189.0)
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs