Assessment Year 1990
Principal Product PAPER MAKER'S WET FELTS
NAICS
n/a
SIC 2299: Textile goods, Not Elsewhere Classified
Sales Range $50
M
to 100
M
# of Employees 250
Plant Area
n/a
Annual Production 612,000
lb
Production Hrs. Annual 7,344
hrs
Location (State) South Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $447,011 8,837,925
kWh
Natural Gas $162,586 28,496
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $163,428 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $162,916

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.8114: Change rate schedules or other changes in utility service $62,710 $15,000 - $62,710
-
MMBtu
02 2.4133: Use most efficient type of electric motors $1,362 $1,268 $1,362
26,964
kWh
-
03 2.4111: Utilize energy-efficient belts and other improved mechanisms $525 - $525
10,258
kWh
-
04 2.7142: Utilize higher efficiency lamps and/or ballasts $389 $295 $389
7,620
kWh
-
05 2.7142: Utilize higher efficiency lamps and/or ballasts $90,960 $210,570 $90,960
1,313,892
kWh
-
06 2.1233: Analyze flue gas for proper air/fuel ratio $6,970 $450 - $6,970
-
MMBtu
07 2.6232: Install set-back timers $512 $1,800 $512
9,965
kWh
-
TOTAL RECOMMENDED $163,428 $229,383 $93,748
1,368,699
kWh
$69,680
-
MMBtu
TOTAL IMPLEMENTED $162,916 $227,583 $93,236
1,358,734
kWh
$69,680
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs