| Assessment Year | 1989 |
|---|---|
| Principal Product | TYVEX COVERALLS |
| NAICS |
n/a
|
| SIC | 2326: Men's and Boys' Work Clothing |
| Sales Range | $10 M to 50M |
| # of Employees | 213 |
| Plant Area |
n/a
|
| Annual Production | 6,000,000
pieces
|
| Production Hrs. Annual | 2,125
hrs
|
| Location (State) | Alabama |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $40,276 | 579,132 |
kWh
|
$0.070 |
| Natural Gas | $4,858 | 847 |
MMBtu
|
$5.74 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $8,192 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,576 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,140 | $10,175 |
$4,140
58,617
kWh
|
- | |
| 02 | 2.7447: Install vinyl strip / high speed / air curtain doors | $2,150 | $3,460 | - |
$2,150
-
MMBtu
|
|
| 03 | 2.4221: Install compressor air intakes in coolest locations | $185 | $75 |
$185
2,638
kWh
|
- | |
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $185 | - |
$185
3,224
kWh
|
- | |
| 05 | 2.4133: Use most efficient type of electric motors | $66 | $75 |
$66
879
kWh
|
- | |
| 06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,466 | - |
$1,466
21,102
kWh
|
- | |
| TOTAL RECOMMENDED | $8,192 | $13,785 |
$6,042
86,460
kWh
|
$2,150
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $4,576 | $10,325 |
$4,576
65,358
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs