Assessment Year 1988
Principal Product PLASTIC PAILS W/ COVERS
NAICS
n/a
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 65
Plant Area
n/a
Annual Production 20,000,000
pieces
Production Hrs. Annual 8,736
hrs
Location (State) Georgia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $444,395 9,291,911
kWh
Natural Gas $17,964 3,001
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $85,826 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.8114: Change rate schedules or other changes in utility service $15,546 $18,000 $15,546
-
kWh
-
02 2.4322: Use or replace with energy efficient substitutes $62,540 $136,000 $62,540
1,743,845
kWh
-
03 2.7122: Disconnect ballasts $1,130 $1,450 $1,130
22,274
kWh
-
04 2.6232: Install set-back timers $2,420 - $2,420
111,079
kWh
-
05 2.7142: Utilize higher efficiency lamps and/or ballasts $140 $525 $140
2,638
kWh
-
06 2.2511: Insulate bare equipment $126 $60 - $126
-
MMBtu
07 2.7447: Install vinyl strip / high speed / air curtain doors $2,070 $3,600 - $2,070
-
MMBtu
08 2.4133: Use most efficient type of electric motors $1,415 $1,068 $1,415
27,843
kWh
-
09 2.4111: Utilize energy-efficient belts and other improved mechanisms $439 $750 $439
8,792
kWh
-
TOTAL RECOMMENDED $85,826 $161,453 $83,630
1,916,471
kWh
$2,196
-
MMBtu
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs