| Assessment Year | 1985 |
|---|---|
| Principal Product | BOTTLE FILLING MACHINES |
| NAICS |
n/a
|
| SIC | 3565: Packaging Machinery |
| Sales Range | $1 M to 5M |
| # of Employees | 50 |
| Plant Area |
n/a
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 4,080
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $82,887 | 1,298,652 |
kWh
|
$0.064 |
| Natural Gas | $6,641 | 1,018 |
MMBtu
|
$6.52 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $11,233 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $3,931 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,922 | $500 |
$2,922
45,721
kWh
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $932 | $1,249 |
$932
14,654
kWh
|
|
| 03 | 2.4221: Install compressor air intakes in coolest locations | $257 | $300 |
$257
4,103
kWh
|
|
| 04 | 2.7251: Reduce air conditioning load by evaporating water from roof | $965 | $8,000 |
$965
14,947
kWh
|
|
| 05 | 2.4133: Use most efficient type of electric motors | $77 | $480 |
$77
1,172
kWh
|
|
| 06 | 2.7243: Improve air circulation with destratification fans / other methods | $6,080 | $15,000 |
$6,080
94,959
kWh
|
|
| TOTAL RECOMMENDED | $11,233 | $25,529 |
$11,233
175,556
kWh
|
||
| TOTAL IMPLEMENTED | $3,931 | $2,229 |
$3,931
61,547
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs