| Assessment Year | 2000 |
|---|---|
| Principal Product | Pump, switches, and alarms |
| NAICS |
n/a
|
| SIC | 3829: Measuring and Controlling Devices, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 200 |
| Plant Area |
60,800
ft2
|
| Annual Production | 900,000
pieces
|
| Production Hrs. Annual | 4,654
hrs
|
| Location (State) | Minnesota |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $42,135 | 1,522,274 |
kWh
|
$0.028 |
| Electricity Demand | $3,836 | 672 |
kW-mo/yr
|
$5.71 |
| Electricity Fees | $6,145 | - |
|
- |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $54,499 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $54,499 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7314: Reduce ventilation air | $8,393 | $4,500 |
$8,393
299,824
kWh
|
- | |
| 02 | 2.6231: Utilize controls to operate equipment only when needed | $403 | $238 |
$403
14,361
kWh
|
- | |
| 03 | 2.7135: Install occupancy sensors | $300 | $540 |
$300
10,844
kWh
|
- | |
| 04 | 4.446: Automate finishing process | $45,038 | $6,995 | - | $45,038 | |
| 05 | 4.611: Begin a practice of predictive / preventative maintenance | $365 | - | - | $365 | |
| TOTAL RECOMMENDED | $54,499 | $12,273 |
$9,096
325,029
kWh
|
$45,403 | ||
| TOTAL IMPLEMENTED | $54,499 | $12,273 |
$9,096
325,029
kWh
|
$45,403 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs