| Assessment Year | 1996 |
|---|---|
| Principal Product | Silos and Silo Unloaders |
| NAICS |
n/a
|
| SIC | 3272: Concrete Products, Except Block and Brick |
| Sales Range | $5 M to 10M |
| # of Employees | 80 |
| Plant Area |
93,843
ft2
|
| Annual Production | 850
lb
|
| Production Hrs. Annual | 4,355
hrs
|
| Location (State) | Minnesota |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $23,356 | 473,036 |
kWh
|
$0.049 |
| Electricity Demand | $16,695 | 2,783 |
kW-mo/yr
|
$6.00 |
| Electricity Fees | $261 | - |
|
- |
| LPG | $24,684 | 5,301 |
MMBtu
|
$4.66 |
| Fuel Oil #2 | $20,696 | 4,158 |
MMBtu
|
$4.98 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $5,481 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,580 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Fuel Oil #2 Savings | Solid Waste (non-haz) Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $286 | $3,907 |
$142
2,931
kWh
|
$144
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $700 | $1,252 |
$390
7,913
kWh
|
$310
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.7447: Install vinyl strip / high speed / air curtain doors | $1,131 | $800 | - | - |
$1,131
-
MMBtu
|
- | - | |
| 04 | 2.2441: Preheat boiler makeup water with waste process heat | $190 | $603 | - | - | - |
$190
-
MMBtu
|
- | |
| 05 | 2.2511: Insulate bare equipment | $228 | $137 | - | - | - |
$228
-
MMBtu
|
- | |
| 06 | 2.2136: Install / repair insulation on steam lines | $169 | $379 | - | - | - |
$169
-
MMBtu
|
- | |
| 07 | 3.5311: Recover and reuse waste material | $901 | - | - | - | - | - |
$901
-
lb
|
|
| 08 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,564 | - | - | - | - |
$1,564
-
MMBtu
|
- | |
| 09 | 2.4221: Install compressor air intakes in coolest locations | $312 | $150 |
$312
6,448
kWh
|
- | - | - | - | |
| TOTAL RECOMMENDED | $5,481 | $7,228 |
$844
17,292
kWh
|
$454
-
kW-mo/yr
|
$1,131
-
MMBtu
|
$2,151
-
MMBtu
|
$901
-
lb
|
||
| TOTAL IMPLEMENTED | $4,580 | $7,228 |
$844
17,292
kWh
|
$454
-
kW-mo/yr
|
$1,131
-
MMBtu
|
$2,151
-
MMBtu
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Fuel Oil #2 Savings | Solid Waste (non-haz) Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs