ITAC Assessment: DS0026
ITAC logo
ITAC Assessment: DS0026
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1995
Principal Product Mowers, Ditchers
NAICS
n/a
SIC 3524: Lawn and Garden Tractors and Home Lawn and Garden Equipment
Sales Range $1
M
to 5
M
# of Employees 150
Plant Area 62,906
ft2
Annual Production 1,000
pieces
Production Hrs. Annual 3,120
hrs
Location (State) South Dakota

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $23,899 331,770
kWh
Natural Gas $9,920 2,134
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $7,467 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $367

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $2,787 $8,639 $2,787
38,394
kWh
-
02 2.7135: Install occupancy sensors $305 $900 $305
9,086
kWh
-
03 2.7261: Install timers and/or thermostats $1,567 $1,050 - $1,567
-
MMBtu
04 2.7231: Use radiant heater for spot heating $2,387 $6,000 - $2,387
-
MMBtu
05 2.4133: Use most efficient type of electric motors $367 $970 $367
3,517
kWh
-
06 2.4221: Install compressor air intakes in coolest locations $54 $168 $54
1,465
kWh
-
TOTAL RECOMMENDED $7,467 $17,727 $3,513
52,462
kWh
$3,954
-
MMBtu
TOTAL IMPLEMENTED $367 $970 $367
3,517
kWh
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs